DocumentCode :
3738367
Title :
Internal pressure diagnostic of vacuum circuit breaker based on the phenomenon of chopping current
Author :
Waldemar Chmielak;Zbigniew Pochanke
Author_Institution :
Institute of Electrical Power Engineering, Warsaw University of Technology, Poland
fYear :
2015
Firstpage :
1
Lastpage :
6
Abstract :
This article presents one of the methods proposed in the literature for examining the status of the vacuum by measuring the chopping current. This phenomenon was studied in a chamber with a pressure control where chopped AC and DC currents were measured. A method of statistical analysis of arcing time and chopped current based on Weibull distribution was developed. The results give rise to a continuation of its practical application.