DocumentCode :
3741660
Title :
Development of a triangular micro well for single cell trapping ? Computational study
Author :
Tewan Tongmanee;Alongkorn Pimpin;Werayut Srituravanich;Wutthinan Jeamsaksiri;Witsaroot Sripumkhai;Dettachai Ketpun;Achariya Sailasuta;Prapruddee Piyaviriyakul
Author_Institution :
Department of Mechanical Engineering, Faculty of Engineering Chulalongkorn University, Thailand
fYear :
2015
Firstpage :
1
Lastpage :
4
Abstract :
The aim of this study is to find appropriate parameters of a trapping device, i.e. equilateral triangular microwell array, using a computational simulation. This simulation was divided into nine cases of microwell with various depths and widths to help analyze the effects of them on velocity and vorticity distribution induced inside the microwell. The microwells with equilateral length of 40, 60 and 80μm, and each length consisted of three depths, i.e. 15, 30 and 45 μm, were studied. The results suggested that the equilateral triangular 40-μm microwell with the depth of 30 μm should be able to effectively trap a 10-20 μm particle.
Keywords :
"Charge carrier processes","Arrays","Fluids","Computational modeling","Boundary conditions","Analytical models","Force"
Publisher :
ieee
Conference_Titel :
Biomedical Engineering International Conference (BMEiCON), 2015 8th
Type :
conf
DOI :
10.1109/BMEiCON.2015.7399540
Filename :
7399540
Link To Document :