DocumentCode
3750124
Title
Single trial visual evoked potential extraction using fast PLS
Author
Duma Kristina Yanti;Mohd Zuki Yusoff;Mones Bekdash;Vijanth Sagayan Asirvadam
Author_Institution
Center for Intelligent Signal and Imaging Research (CISIR) Electrical and Electronics Engineering Department, Universiti Teknologi PETRONAS Perak, Malaysia
fYear
2015
Firstpage
419
Lastpage
422
Abstract
This paper evaluates the single trial extraction of Visual Evoked Potential (VEP) signal. Single trial extraction of VEP contributes in the integration of fMRI-EEG application as well as in the Brain Computer Interface application. The extraction is performed by using the Fast Partial Least Square (PLS) algorithm. The extraction of the desired VEP signals, both in artificial and real Electroencephalography (EEG) signal is quantified. Moreover, the latency or average error rates of P100, P200 and P300 in the artificial signal have been measured. The results illustrate the advantages and drawbacks of the algorithm in the single trial VEP extraction case.
Keywords
"Electroencephalography","Visualization","Error analysis","Conferences","Linear programming","Electric potential","Noise measurement"
Publisher
ieee
Conference_Titel
Signal and Image Processing Applications (ICSIPA), 2015 IEEE International Conference on
Type
conf
DOI
10.1109/ICSIPA.2015.7412227
Filename
7412227
Link To Document