• DocumentCode
    3757480
  • Title

    Dynamic detection and depth location of pipette tip in microinjection

  • Author

    Fujun Sun;Peng Pan;Jun He;Feiyu Yang;Changhai Ru

  • Author_Institution
    Research Center of Robotics and Micro System & Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou, 215021, China
  • fYear
    2015
  • Firstpage
    90
  • Lastpage
    93
  • Abstract
    As cells are injected with micro-pipettes which operated by micro manipulator under powerful microscopes, the accuracy rate and success rate of micro-injection are determined by the pipette tip location and the depth down to the surface of petri dish. In this paper, the dynamic tip detection was realized by setting regions of interest in the images, handling the regions´ images with Gaussian filter, binarizing the images with OTSU algorithm, selecting tip contour in the binarized images and traversaling all the points of the contour to get the most right point´s coordinates. Then, lower the height in the Z direction with slow and uniform speed. The tip coordinates in the X direction were compared in time to judge whether the tip was down to the surface of petri dish. The location where the tip just contacted the dish surface was defined as the depth origin which the depth location was based on. The experiment results show that using the contour recognition method could obtain accurate tip location and depth location, and the success rate is more than 80%.
  • Keywords
    "Microinjection","Image recognition","Surface treatment","Manipulators","Microscopy","Sun"
  • Publisher
    ieee
  • Conference_Titel
    Manipulation, Manufacturing and Measurement on the Nanoscale (3M-NANO), 2015 International Conference on
  • Type

    conf

  • DOI
    10.1109/3M-NANO.2015.7425456
  • Filename
    7425456