DocumentCode :
3757758
Title :
Chapter V the breakdown of dielectrics
Author :
J. J. Chapman;L. J. Frisco
Author_Institution :
The Johns Hopkins University, Dielectrics Laboratory, Baltimore, Md., United States
fYear :
1957
Firstpage :
91
Lastpage :
109
Abstract :
Persson (1) derives the limitations of the conventional microwave cavity method of measuring electron density. Microscopic electric polarization can be eliminated and overlapping modes suppressed by designing the cavity so that the probing microwave field and the plasma have rotational symmetry around the same axis, thereby extending the range of electron density measurement. Following this theoretical development, Buchsbaum and Brown (2) present a method whereby much higher electron densities can be measured. The method, based on eliminating the effect of a-c space charge on the probing microwave field, is accomplished by ensuring that the electric field is everywhere perpendicular to the electron density gradients.
Keywords :
"Nitrogen","Microwave measurement","Mercury (metals)","Ionization","Partial discharges"
Publisher :
ieee
Conference_Titel :
Literature on Dielectrics, Digest of
Type :
conf
Filename :
7425750
Link To Document :
بازگشت