Title :
Investigation of oxygen consumption for micropatterns of contractile myotubes by scanning electrochemical microscopy
Author :
Yuki Igaki;Fumio Mizutani;Tomoyuki Yasukawa
Author_Institution :
Graduate School of Material Science, University of Hyogo, 3-2-1 Koto, Kamigori, Ako, 678-1297, Japan
Abstract :
Scanning electrochemical microscopy (SECM) has been applied to determining the oxygen consumption of individual myotubes. Reduction currents of oxygen monitored by Pt microelectrode positioned above the myotube decreased after the continuous contraction of myotubes was induced by the application of electric pulses.
Keywords :
"Monitoring","Wires","Gold","Electrodes"
Conference_Titel :
Micro-NanoMechatronics and Human Science (MHS), 2015 International Symposium on
DOI :
10.1109/MHS.2015.7438245