DocumentCode
3772648
Title
Long term evaluation of self-bonding magnet wire for hermetic motor system
Author
K. Ito;K. Ueda;K. Nakano;S. Chabata;H. Iizuka;H. Miyako
Author_Institution
Magnet Wire Engineering Department and Materials Development Department, Fujikura, Ltd. Nishigotanda 2-Chorae, Shinagawa-ku, Tokyo, Japan
fYear
1983
Firstpage
309
Lastpage
314
Abstract
At first, we have had long term evaluation of self-bonding magnet wire (SBW5) related to R-22 refrigerant resistant properties for hermetic field since 1981 E/EIC. Secondly, we also have tried the reliability evaluation tests of hermetic motor system applied with SBW5. From these results, we could get a conclusion that reliability of our SBW5 and the hermetic motor system is more excellent than conventional system impregnated with varnish.
Keywords
"Wires","Resistance","Reliability","Bonding","Saturation magnetization","Liquids","Windings"
Publisher
ieee
Conference_Titel
Electrical/Electronical Insulation Conference, 1983 EIC 6th
Print_ISBN
978-1-5090-3114-6
Type
conf
DOI
10.1109/EEIC.1983.7465088