A diagnostics plate is being assembled as part of the linac commissioning plan for the Oak Ridge National Laboratory Spallation. Neutron Source (SNS). The D-Plate will be positioned directly after the first drift tube linac; (DTL) tank, where the H- beam energy will be 7.5 MeV. A full suite of beam diagnostic instrumentation is planned, including profile, current, phase, energy, and emittance measurements. The D-Plate is designed to operate up to the full duty factor of the linac, or up to 16-kW beam power. Until the spallation neutron target is completed several years later, this will be the last time the facility can be operated at full current and duty cycle
Keywords
ion accelerators; linear accelerators; particle beam diagnostics; 16 kW; 7.5 MeV; D-Plate; H; Spallation. Neutron Source; beam diagnostics; current measurement; diagnostics plate; emittance measurement; energy measurement; linac; phase measurement; Apertures; Current measurement; Energy measurement; Instruments; Linear particle accelerator; Magnets; Monitoring; Position measurement; Power measurement; Wire;