DocumentCode
384010
Title
Numerical calculation of air gap magnetic field of a salient synchronous generator with the consideration of the effect of turn insulation
Author
Dong, Zhang ; Weili, Li ; Feng, Zhou ; Yunpeng, Hou
Author_Institution
Coll. of Electr. & Electron. Eng., Harbin Univ. of Sci. & Technol., China
Volume
2
fYear
2002
fDate
2002
Firstpage
774
Abstract
According to the theory of electromagnetic fields, the air gap magnetic field of a large salient synchronous generator with a fractional stator slot is calculated by the finite element method with and without the consideration of turn insulation in this paper. By analyzing the air gap magnetic field, stray loss on the surface of rotor can be worked out and moreover temperature field distribution in rotor can be obtained. Calculation results with and without the consideration of turn insulation are compared and the effect of turn insulation to the air gap magnetic field and rotor temperature field is analyzed. The Longyang Gorge 320 MW hydro generator is taken as an example and the calculation results and the measured results are compared to test the accuracy of the calculation.
Keywords
finite element analysis; hydroelectric generators; machine insulation; machine theory; magnetic fields; rotors; stators; synchronous generators; 320 MW; EM field theory; air gap magnetic field; fractional stator slot; rotor surface stray loss; rotor temperature field; salient synchronous hydroelectric generator; turn insulation effects; Electromagnetic fields; Finite element methods; Insulation; Magnetic analysis; Magnetic field measurement; Magnetic fields; Magnetic losses; Rotors; Stators; Synchronous generators;
fLanguage
English
Publisher
ieee
Conference_Titel
Power System Technology, 2002. Proceedings. PowerCon 2002. International Conference on
Print_ISBN
0-7803-7459-2
Type
conf
DOI
10.1109/ICPST.2002.1047504
Filename
1047504
Link To Document