• DocumentCode
    389746
  • Title

    Transient current analysis of induction generator for wind power generating system

  • Author

    Senjyu, Tomonobu ; Sueyoshi, Norihide ; Uezato, Katsurni ; Fujita, Hideki

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Ryukyus Univ., Okinawa, Japan
  • Volume
    3
  • fYear
    2002
  • fDate
    6-10 Oct. 2002
  • Firstpage
    1647
  • Abstract
    In this paper, we present transient current analysis of induction generators used in wind power system before and after three-phase fault conditions. At first basic equations of induction generator, connected to infinite bus, are developed and then transient current analysis formulas are deduced for a three-phase fault before and after fault clearance. Furthermore, it is derived that the initial phase angle for the three-phase fault or restore phase angle of power supply voltages and the time at which maximum or minimum transient currents flow in the system.
  • Keywords
    asynchronous generators; electrical faults; transient analysis; wind power plants; fault clearance; induction generator; infinite bus; initial phase angle; maximum transient currents flow; minimum transient currents flow; power supply voltages; restore phase angle; short-circuit current; three-phase fault; three-phase fault conditions; transient current analysis; wind power generating system; Equations; Induction generators; Power generation; Power supplies; Power system restoration; Power system transients; Transient analysis; Voltage; Wind energy; Wind energy generation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Transmission and Distribution Conference and Exhibition 2002: Asia Pacific. IEEE/PES
  • Print_ISBN
    0-7803-7525-4
  • Type

    conf

  • DOI
    10.1109/TDC.2002.1176847
  • Filename
    1176847