DocumentCode
389972
Title
Simulation of industrial AC drive system under fault conditions
Author
Weatherford, Harry H. ; Brice, Charles W.
Author_Institution
Georgetown Steel Co., SC, USA
Volume
1
fYear
2003
fDate
9-13 Feb. 2003
Firstpage
457
Abstract
An industrial motor drive suffers from periodic failures of the DC link aluminum electrolytic capacitor bank. Simulations pinpoint likely causes, including problems with the design of the balancing resistors. Stress on the capacitor can be produced by faults in the inverter and by open-conductor faults in the balancing resistors.
Keywords
capacitor storage; electrical faults; electrolytic capacitors; induction motor drives; invertors; resistors; steel industry; 13.8 kV; 1500 kVA; 1500 kW; 700 V; 950 V; DC link aluminum electrolytic capacitor bank; balancing resistors; capacitor stress; industrial AC drive system; industrial motor drive; inverter faults; open-conductor faults; periodic failures; steel industry; AC motors; Capacitors; Circuit faults; Inverters; Metals industry; Motor drives; Rectifiers; Resistors; Synchronous motors; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference and Exposition, 2003. APEC '03. Eighteenth Annual IEEE