DocumentCode
404929
Title
A comparative study of line start permanent magnet, skeleton type brushless and snail-cam type switched reluctance motor for a fan
Author
LEE, Ji Young ; LEE, Geun Ho ; Hong, Jung Pyo ; Jin Hur
Author_Institution
Dept. of Electr. Eng., Changwon Nat. Univ., South Korea
Volume
1
fYear
2003
fDate
9-11 Nov. 2003
Firstpage
183
Abstract
The objective of this paper is to provide a comparison between the line start permanent magnet, skeleton type brushless DC and snail-cam type switched reluctance motor. These motors are compared under the same load characteristic as a cooling fan motor of a refrigerator. The comparison consists of speed, output power, efficiency, copper loss and cost for three different motors. For the given application, the results provide an indication of the best machine suited with respect to performance and cost.
Keywords
brushless DC motors; cooling; permanent magnet motors; refrigerators; reluctance motors; cooling fan motor; line start permanent magnet; load characteristic; refrigerator; skeleton type brushless DC motors; snail-cam type switched reluctance motor; Brushless DC motors; Cooling; Costs; DC motors; Magnetic switching; Permanent magnet motors; Reluctance motors; Skeleton; Synchronous motors; Torque;