    UWB Source Localization by Using the Pseudospectral Time-Domain Time-Reversal Method in Biological Tissues

  • Author

    Cruciani, Silvano ; Feliziani, Mauro

  • Author_Institution
    Dept. of Ind. & Inf. Eng. & Econ., Univ. of L´Aquila, L´Aquila, Italy
  • Volume
    51
  • Issue
    3
  • fYear
    2015
  • fDate
    Mar-15
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    The applicability of the time-reversal theory by the pseudospectral time-domain method is investigated to localize a medical implant equipped with an ultrawideband radio and embedded in a randomly lossy dielectric medium. A localization algorithm is implemented and tested for various test cases. A comparative analysis with the finite difference time-domain method implementation is performed in terms of memory occupation and computational time.
  • Keywords
    biological tissues; finite difference time-domain analysis; prosthetics; ultra wideband communication; UWB source localization; biological tissues; finite difference time-domain method; medical implant; memory occupation; pseudospectral time-domain time-reversal method; random lossy dielectric medium; ultrawideband radio; Conductivity; Electromagnetic scattering; Finite difference methods; Media; Observers; Permittivity; Time-domain analysis; Finite difference time-domain (FDTD); locating system; pseudospectral method; time reversal (TR); ultrawideband (UWB) technology;