  • Abstract
    The performance of an X-ray imaging detector is generally evaluated by considering its detective quantum efficiency (DQE), which measures the ability of the detector to preserve the image information contained in the incident X-ray fluence. The DQE is also an important factor in figures-of-merit used to compare the performance of various radiographic machines and experimental setups. A simple expression is derived for the DQE of a storage-phosphor imaging plate (SPIP) and it is calculated as a function of the incident X-ray energy. The results are compared with measured data acquired from exposing the SPIP to Co/sup 60/ gamma radiation. An excellent agreement with theory is obtained.
  • Keywords
    Monte Carlo methods; X-ray imaging; cobalt; gamma-rays; phosphors; radiography; Co/sup 60/ gamma radiation; Monte Carlo study; X-ray energy; X-ray imaging detector; detective quantum efficiency; image information; radiographic machines; storage phosphor imaging plate; Energy storage; Gamma rays; Image storage; Monte Carlo methods; Optical imaging; Phosphors; Radiography; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2003. Digest of Technical Papers. PPC-2003. 14th IEEE International
  • Conference_Location
    Dallas, TX, USA
  • Print_ISBN
    0-7803-7915-2
  • Type

    conf

  • DOI
    10.1109/PPC.2003.1277666
  • Filename
    1277666