• DocumentCode
    405950
  • Title

    Angular dose variations from 4- to 6-MV rod-pinch diode experiments on the ASTERIX pulsed-power generator

  • Author

    Swanekamp, S.B. ; Allen, R.J. ; Commisso, R.J. ; Cooperstein, G. ; Mosher, D. ; Young, F.C. ; Vermare, C. ; Delvaux, J. ; Horde, Y. ; Merle, E. ; Nicolas, R. ; Nore, D. ; Pierret, O. ; Rosol, Y.R. ; Tailleur, Y. ; Veron, L. ; Bayol, F. ; Garrigues, A. ; D

  • Author_Institution
    Div. of Plasma Phys., Naval Res. Lab., Washington, DC, USA
  • Volume
    1
  • fYear
    2003
  • fDate
    15-18 June 2003
  • Firstpage
    483
  • Abstract
    The angular distribution of radiation from a rod-pinch diode is examined with coupled PIC-Monte-Carlo simulations using the LSP code (D.R. Welch, et al., 2001) and compared with angular dose measurements on the ASTERIX pulsed-power generator. For the 4- to 6-MV voltage range accessible in the experiments, both the measured and simulated doses at 1 m were 25 to 38 rad-LiF in the forward direction (0/spl deg/). The calculated dose at 90/spl deg/ is 1.2-1.8 times larger than the forward-directed dose depending on both the voltage and rod diameter. This is also in agreement with the measured angular variation (F.C. Young, et al.,). At 6 MV, the simulations show that the dose near 180/spl deg/ is more than twice the forward-directed dose. At these high voltages, electrons approach the anode rod primarily at angles close to 180/spl deg/ resulting in peak radiation in the backward direction. This suggests that negative polarity should be considered for voltages at or above 6 MV to maximize the extracted dose. Simulations show that the 0/spl deg/ dose is higher with tapered rods and increases with rod diameter. Simulations at 10 MV show that the dose near 180/spl deg/ is more than ten times higher than the 0/spl deg/ dose. At 10 MV, the dose near 180/spl deg/ at 1 m from a 2-mm diameter, blunt rod is calculated to be /spl sim/800 Rad (LiF).
  • Keywords
    Monte Carlo methods; angular measurement; lithium compounds; p-i-n diodes; pulse generators; thermoluminescent dosimeters; 10 MV; 4 MV; 6 MV; ASTERIX pulsed-power generator; LSP code; LiF; PIC-Monte-Carlo simulation; angular dose measurement; angular variation measurement; backward direction; blunt rod; forward-directed dose; radiation angular distribution; rod-pinch diode; Anodes; Cathodes; Diodes; Electrons; Gold; Laboratories; Pulse generation; Pulse measurements; Tungsten; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2003. Digest of Technical Papers. PPC-2003. 14th IEEE International
  • Conference_Location
    Dallas, TX, USA
  • Print_ISBN
    0-7803-7915-2
  • Type

    conf

  • DOI
    10.1109/PPC.2003.1277756
  • Filename
    1277756