Abstract
New beam lines are presently under construction for ELSA, a 18 MeV electron linac located at Bruyeres-Le-Chatel. These lines need a beam position measurement system filling the following requirements: small space occupancy, good sensitivity, wide dynamic range (more than 90 dB), high noise immunity, single-bunch/multibunch capability. We designed a compact 4-stripline sensor, and an electronic treatment chain based on log-amplifiers. This paper presents the design, cold and hot test results.
Keywords
beam handling techniques; electron accelerators; particle beam bunching; particle beam diagnostics; particle beam dynamics; storage rings; 18 MeV; 4-stripline sensor; ELSA-2; electron linac; electronic treatment; high dynamic range beam position measurement system; high noise immunity; log-amplifiers; multibunch capability; sensitivity; single-bunch capability; space occupancy; Consumer electronics; Dynamic range; Extraterrestrial measurements; Frequency; Impedance matching; Linear particle accelerator; Position measurement; Stripline; Structural beams; Testing;