DocumentCode
409161
Title
New insertion device vacuum chambers at the Advanced Photon Source
Author
Trakhtenberg, Emil ; Wiemerslage, Greg ; DenHartog, Patric ; Brajuskovic, Branislav
Author_Institution
Adv. Photon Source, Argonne Nat. Lab., IL, USA
Volume
2
fYear
2003
fDate
12-16 May 2003
Firstpage
830
Abstract
Six new types of insertion device vacuum chambers have been designed at the Advanced Photon Source (APS). One chamber has been designed for the APS canted undulator beamlines, two for the Canadian Light Source (CLS), and three for BESSY II. For the double canted undulators and CLS, a new extrusion shape with an oval aperture (not elliptical as usual) was developed and extruded. That required a thorough stress analysis and some compromise, which included a small increase of the vacuum chamber wall thickness. The details of the stress analyses and design of the chambers, along with lessons learned, are presented.
Keywords
beam handling equipment; electron accelerators; particle beam dynamics; storage rings; vacuum apparatus; APS canted undulator beamlines; Advanced Photon Source; BESSY II; Canadian Light Source; insertion device vacuum chambers; stress analysis; vacuum chamber wall thickness; Apertures; Laboratories; Laser sintering; Light sources; Manufacturing; Shape; Stress; Synchrotron radiation; Undulators; Virtual colonoscopy;