• DocumentCode
    426882
  • Title

    Striping in Disk Array RM2 Enabling the Tolerance of Double Disk Failures

  • Author

    Park, Chan-Ik ; Choe, Tae-Young

  • Author_Institution
    POSTECH, Korea
  • fYear
    1996
  • fDate
    1996
  • Firstpage
    46
  • Lastpage
    46
  • Abstract
    There is a growing demand in high reliability beyond what current RAID can provide and there are various levels of user demand for data reliability. An efficient data placement scheme called RM2 has been proposed in [Efficient Placement of Parity and Data To Tolerate Two Disk Failures In Disk Array Systems], which makes a disk array system tolerable against double disk failures. In this paper, we consider how to choose an optimal striping unit for RM2 particularly when no workload information is available except read/write ratio. A disk array simulator for RM2 has been developed for experimental works. It is shown that RM2 has an optimal striping unit of two and half tracks in the case of disk read operations, and one third of a single track if any disk write operations are involved.
  • Keywords
    data placement; disk array; performance; reliability; striping; data placement; disk array; performance; reliability; striping;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Supercomputing, 1996. Proceedings of the 1996 ACM/IEEE Conference on
  • Print_ISBN
    0-89791-854-1
  • Type

    conf

  • DOI
    10.1109/SUPERC.1996.183548
  • Filename
    1392917