    Analysis on the influence of tissues/organs´ movements in EIT images of lung ventilation using finite difference thorax models

  • Author

    Zhang, J. ; Patterson, R.P.

  • Author_Institution
    Biophys. Sci. & Med. Phys. & Biomed. Eng. Inst., Minnesota Univ., USA
  • Volume
    1
  • fYear
    2004
  • fDate
    1-5 Sept. 2004
  • Firstpage
    1557
  • Lastpage
    1560
  • Abstract
    Monitoring lung air and fluid volume is a promising EIT application. Respiratory activity causes both chest expansion and position changes of tissues/organs in the thorax, which contributes measurement error. In EIT application, the electrodes are placed around chest in a two-dimensional ring, and image is reconstructed on the assumption that the object is two-dimensional and the images are due to resistivity change. EIT reconstruction algorithms generally do not consider organ and tissue positional change. Finite difference models (FDM) were developed based on MR images with different air volumes and used to study the effect of tissues/organs´ motion. Results show that the tissues/organs´ motion influence the region around the heart, which introduce the artifacts in the middle anterior region. The tissues/organs´ motion also increases the resistivity change in the lung regions, which cannot be neglected. We conclude that tissues/organs´ motion can cause serious error in the interpretation of EFT ventilation images.
  • Keywords
    bioelectric phenomena; biological organs; biological tissues; biomedical MRI; biomedical electrodes; biomedical measurement; cardiology; electric impedance imaging; finite difference methods; image reconstruction; lung; measurement errors; medical image processing; patient monitoring; pneumodynamics; biomedical electrode; chest expansion; electrical impedance tomography; finite difference thorax model; image reconstruction; lung air monitoring; lung ventilation; measurement error; organ movement; reconstruction algorithm; resistivity change; respiratory activity; tissue movement; Conductivity; Electrodes; Finite difference methods; Image analysis; Lungs; Measurement errors; Monitoring; Thorax; Tomography; Ventilation; EIT; Electrical Impedance Tomography; Finite difference model; ventilation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-8439-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2004.1403475
  • Filename
    1403475