DocumentCode
435450
Title
A practical formula to calculate critical value of the interphase reactor in a six-phase diode rectifier with tap-changer
Author
Pan, Qijun ; Ma, Weiming ; Liu, Dezhi
Author_Institution
Res. Inst. of Power Electron. Technol., Naval Univ. of Eng., Wuhan, China
Volume
1
fYear
2004
fDate
2-6 Nov. 2004
Firstpage
696
Abstract
This paper presents a formula to calculate the critical value of interphase reactor (IPR) in a six-phase rectifier with tap-changer. Simulation and experimental results verify the validity of the calculation approach. The calculated critical value is accurate enough to meet the engineering need. The parameter of the reactor must be larger than the critical value. On the basis of theoretical analysis, a simple and effective method is provided to design the interphase reactor. On balance, the above achievements play an important role in the design of the interphase reactor.
Keywords
harmonic distortion; on load tap changers; power conversion harmonics; power supply quality; rectifying circuits; interphase reactor; power quality; six-phase diode rectifier; tap-changers; voltage harmonic distortion; Bridge circuits; Diodes; Harmonic analysis; Inductors; Intellectual property; Paper technology; Performance analysis; Power electronics; Rectifiers; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics Society, 2004. IECON 2004. 30th Annual Conference of IEEE
Print_ISBN
0-7803-8730-9
Type
conf
DOI
10.1109/IECON.2004.1433395
Filename
1433395
Link To Document