• DocumentCode
    441804
  • Title

    Selection of the optimal initial steam pressure for coal-fired power units

  • Author

    Zhang, Chun-Fa ; Li, Yong-Ling ; Wang, Hui-Jie ; Xie, Fei ; Huang, Yu ; Bao Zhang

  • Author_Institution
    North China Electr. Univ. of Power Eng., Baoding, China
  • Volume
    3
  • fYear
    2005
  • fDate
    18-21 Aug. 2005
  • Firstpage
    1835
  • Abstract
    One of the main shortages of thermodynamic system analysis in coal fired power plants is the lack of optimal value of initial parameters under present operating condition. In this paper, a mathematical model is given to solve the problem with the systemic analysis method for the first time. Through quantitative calculations of N300-16.7/537/537-3 unit of a certain thermal power plant, the optimal initial pressure is obtained by method of exhaustion. It is the foundation of the optimal control in the whole power plant. The limitation of optimal operation curve provided by manufactory is also analyzed in this paper.
  • Keywords
    control system analysis; optimal control; power system control; pressure control; steam power stations; coal-fired power units; exhaustion; mathematical model; optimal control; optimal initial steam pressure; optimal operation curve; quantitative calculation; sliding pressure operation; specific heat consumption; steam turbine; systemic analysis; thermal power plant; thermodynamic system analysis; Mathematical model; Optimal control; Power engineering; Power generation; Power generation economics; Security; System testing; Thermodynamics; Turbines; Valves; Steam turbine; optimal initial steam pressure; sliding pressure operation; specific heat consumption;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Machine Learning and Cybernetics, 2005. Proceedings of 2005 International Conference on
  • Conference_Location
    Guangzhou, China
  • Print_ISBN
    0-7803-9091-1
  • Type

    conf

  • DOI
    10.1109/ICMLC.2005.1527244
  • Filename
    1527244