Abstract
The paper first describes the principles of remote sensing of atmospheric water vapor content and liquid water content with dual-channel millimeter wave radiometer whose central frequency is 35 GHz and 21.7 GHz respectively in detail. The block diagram and parameters of the radiometer system is given in the paper. Some experiment results measured with dual-channel millimeter wave radiometer and dual-frequency GPS receiver are given and compared at the end of the discussion.
Keywords
Global Positioning System; atmospheric humidity; atmospheric techniques; millimetre wave measurement; radiometers; receivers; remote sensing; 21.7 GHz; 35 GHz; atmospheric water vapor content; dual-channel millimeter wave radiometer; dual-frequency GPS receiver; global positioning system; liquid water content; remote sensing; Atmosphere; Atmospheric waves; Electromagnetic heating; Electromagnetic wave absorption; Equations; Frequency; Microwave radiometry; Millimeter wave measurements; Remote sensing; Weather forecasting;