DocumentCode :
453591
Title :
Moisture detection of materials in leaky cavities using microwave techniques
Author :
Penirschke, Andreas ; Schiissler, M. ; Vossiek, Martin ; Gulden, Peter ; Jakoby, Rolf
Author_Institution :
Inst. fuer Hochfrequenztechnik, Technische Univ. Darmstadt, Germany
Volume :
2
fYear :
2005
fDate :
4-6 Oct. 2005
Abstract :
In order to characterize the moisture of material samples in a leaky, rotating cavity without influencing the process, use was made of microwave techniques to determine the amount of water within the cavity. Moisture measurements where done before and during rotation of the cavity. The extraction of the humidity has been carried out using a mode tracking algorithm as well as a classification algorithm based on a maximum likelihood approach.
Keywords :
humidity measurement; maximum likelihood detection; microwave measurement; pattern classification; leaky cavities; maximum likelihood approach; microwave techniques; mode tracking algorithm; moisture detection; moisture measurements; Dielectric constant; Dielectric losses; Dielectric materials; Frequency; Leak detection; Microwave technology; Microwave theory and techniques; Moisture; Neural networks; Scattering parameters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference, 2005 European
Print_ISBN :
2-9600551-2-8
Type :
conf
DOI :
10.1109/EUMC.2005.1610195
Filename :
1610195
Link To Document :
بازگشت