    Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET

  • Author

    Watson, Charles C.

  • Author_Institution
    Siemens Med. Solutions Molecular Imaging, Knoxville, TN
  • Volume
    3
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    1736
  • Lastpage
    1739
  • Abstract
    We have investigated image noise variance in 3D OSEM reconstruction of clinical time-of-flight (TOF) and conventional PET. Patient data were acquired on a biograph 16 PET/CT having 1.25 nsec TOF time resolution. Statistically independent replicate sinograms obtained from sampled listmode data were analyzed. We computed TOF and non-TOF image variance as a function of iteration number and scan time, extrapolated to convergence, and determined the dependence of both converged and post-smoothed image variances on scan duration. We have found that these image variances have an inverse power-law dependence on scan time, but with exponents < 1, likely due to the noise-dependent bias of OSEM. This means that scan time must be increased by more than a factor f in order to reduce image variance by 1/f, and hence that image variance is not inversely proportional to NEC. Image noise variance is found to be 38-48% higher for non-TOF compared to TOF, for equal scan time. For equal variance, conventional reconstruction requires 63-73% longer scan time than does TOF. This scan time advantage is similar to what we have observed in linear reconstruction, and indicates that TOF has a distinct benefit for clinical iterative reconstruction even with 1.25 nsec time resolution.
  • Keywords
    medical image processing; positron emission tomography; 3D OSEM reconstruction; biograph 16 PET/CT; clinical iterative image reconstruction; clinical time-of-flight PET; image noise variance; ordered subset expectation maximisation; positron emission tomography; sinograms; Computed tomography; Convergence; Data analysis; Image converters; Image reconstruction; Liver; Molecular imaging; Noise reduction; Nuclear and plasma sciences; Positron emission tomography; Image noise variance; OSEM; PET; TOF; Time-of-flight;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354232
  • Filename
    4179345