    Optimizing Acquisition Parameters in TOF PET Scanners

  • Author

    Surti, Suleman ; Fakhri, Georges El ; Karp, Joel S.

  • Author_Institution
    Pennsylvania Univ., Philadelphia, PA
  • Volume
    4
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    2354
  • Lastpage
    2359
  • Abstract
    Noise equivalent counts (NEC) have been used as a measure of PET image quality for many years. As a result, clinical patient dosage and scan times have been determined based upon this figure of merit. Since NEC represents a global measure of signal-to-noise ratio (SNRNEC) in non time-of-flight (Non TOF) PET, we used a lesion detectability metric (channelized hotelling observer signal-to-noise ratio, CHO SNR) to better assess the impact of patient dosage, scan time and time-of-flight (TOF) PET on image quality. Our results indicate that there is a linear relationship between SNRNEC and CHO SNR for most singles rate or activity levels, with an increase in SNRnec due to either increased scan time or increased activity leading to a subsequent increase in CHO SNR. At very high rates, there is an indication that the rate of increase in CHO SNR is lower compared to the gain in SNRNEC as measured on the Gemini TF PET scanner. This reduced gain may be due to some degradation in timing and spatial resolution at high rates. Our results also show that the gain in CHO SNR for a small 20-cm diameter cylinder due to TOF is modest (14%). For a larger 35-cm diameter cylinder we see a greater increase in CHO SNR with TOF (gain of 42%), leading to the possibility of reducing scan time by half, or achieving better lesion detectability over a similar Non TOF scanner.
  • Keywords
    biomedical imaging; image denoising; image scanners; positron emission tomography; 20 cm; 35 cm; CHO SNR; Gemini TF PET scanner; NEC; PET image quality; SNRNEC; TOF PET scanners; acquisition parameter optimization; channelized hotelling observer signal-to-noise ratio; clinical patient dosage; lesion detectability metric; noise equivalent counts; non TOF PET; scan time; time-of-flight PET; Degradation; Gain measurement; Image quality; Lesions; National electric code; Noise measurement; Positron emission tomography; Signal to noise ratio; Time measurement; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.354386
  • Filename
    4179500