  • Abstract
    Quantitative description of the cardiac left ventricle (LV) motion is desirable to assist in detecting myocardial motion abnormalities. It has been recognized that the torsion component of the LV movement is considerably more difficult to track than its radial counterpart. We develop a motion estimation method that estimates three-dimensional (3-D) LV motion vector field (MVF) that includes the twisting motion from four-dimensional (4-D) gated myocardial perfusion (MP) emission computed tomography (ECT) images. The method is implemented through searching for an MVF that minimizes a cost function consisting of the image matching error between two frames and the weighted strain energy constraint that prevents physically implausible movement. The strain energy is calculated on segmented heart voxels with physical parameters that model the material properties of the myocardium. The close-to-optimal weight of the strain energy was obtained by minimizing the root-mean-square errors of the estimated MVF from standard NCAT phantom images simulating gated MP data. The performance of this method has been quantitatively evaluated, in estimating MVF from NCAT generated images with specified motion corresponding to varied LV twisting angles (different from the standard phantom) and to regional LV motion defects. The estimated defect MVF can be distinguished from the estimated normal MVF.
  • Keywords
    biomechanics; cardiology; emission tomography; 4D gated myocardial perfusion ECT; NCAT phantom; cardiac left ventricle motion; cardiac motion estimation; gated emission computed tomography images; myocardial motion abnormality; Capacitive sensors; Computed tomography; Cost function; Electrical capacitance tomography; Image matching; Imaging phantoms; Motion detection; Motion estimation; Myocardium; Tracking; Myocardial motion estimation; gated cardiac emission computed tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.356435
  • Filename
    4179592