DocumentCode
464108
Title
Calorimetry for Power Electronics
Author
Weier, S. D J ; McMahon, R.A. ; Malliband, P.D.
Author_Institution
Cambridge Univ.
Volume
2
fYear
2006
fDate
6-8 Sept. 2006
Firstpage
608
Lastpage
612
Abstract
Calorimetry allows direct, accurate measurements of losses in power electronics systems. A small-scale version of a double chamber, closed type calorimeter for measuring losses up to 20 W is described in this paper. The design comprises an inner chamber with heat exchangers integrated into the top and bottom of the chamber, surrounded by insulation. This is enclosed by a temperature controlled air gap, within a further insulated enclosure. Calibration tests show that losses can be measured to a precision of +/- 0.4 W and ways of improving the accuracy further are discussed
Keywords
calibration; calorimeters; calorimetry; loss measurement; losses; power electronics; -0.4 to 0.4 W; calibration tests; calorimetry; closed type calorimeter; double chamber; heat exchangers; insulated enclosure; loss measurements; power electronics; temperature controlled air gap; Calorimetry; Circuits; Cooling; Electric variables measurement; Insulation; Loss measurement; Power electronics; Power measurement; Temperature control; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Universities Power Engineering Conference, 2006. UPEC '06. Proceedings of the 41st International
Conference_Location
Newcastle-upon-Tyne
Print_ISBN
978-186135-342-9
Type
conf
DOI
10.1109/UPEC.2006.367550
Filename
4218757
Link To Document