• DocumentCode
    468501
  • Title

    The analysis of saturation and coreloss effects of induction motor direct starting

  • Author

    Najafabadi, T.A. ; Nabavi, S.M.

  • Author_Institution
    Univ. of Tehran, Tehran
  • fYear
    2007
  • fDate
    8-11 Oct. 2007
  • Firstpage
    1265
  • Lastpage
    1268
  • Abstract
    Induction motor direct starting may cause faults on both the power net and mechanical load. In other words the first current peak and the first torque peak of induction motors are vital for the power net and mechanical load respectively. A model for induction motors is proposed in [1] considering saturation effects. Although this model attempts to predict the induction motor behavior in direct starting, some differences between simulation and experimental results are perceived. In this paper, firstly the coreloss is taken into account in [1], and then we show that power net voltage initial phase value is impressive in the value of the current first peak in direct starting. Finally, by considering the condition of [1], our method fits experimental results better than [1].
  • Keywords
    induction motors; starting; induction motor direct starting; mechanical load; power net; saturation-coreloss effects; Cause effect analysis; Circuit faults; Control systems; Equivalent circuits; Induction motors; Predictive models; Process control; Stator cores; Torque; Voltage; core loss; direct starting; induction motor; saturation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2007. ICEMS. International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    978-89-86510-07-2
  • Electronic_ISBN
    978-89-86510-07-2
  • Type

    conf

  • Filename
    4411992