DocumentCode
468576
Title
Motor oversizing outlook
Author
Bortoni, Edson Da Costa
Author_Institution
Itajuba Fed. Univ., Itajuba
fYear
2007
fDate
8-11 Oct. 2007
Firstpage
1385
Lastpage
1396
Abstract
Three-phase induction motors are intrinsically efficient machines. Due to its common misapplication they are considered a great potential of energy conservation in industries. This paper presents a set of methodologies and a road map to evaluate if a motor is oversized or not, and proposes some overtaking solutions to increase the energy efficiency of the whole motor-load system.
Keywords
energy conservation; induction motors; energy conservation; motor oversizing outlook; motor-load system; three-phase induction motors; Energy conservation; Energy efficiency; IEC standards; Induction motors; Measurement standards; Potential energy; Roads; Robustness; Steady-state; Testing;