DocumentCode
468637
Title
Effects of a remanent magnetization on the sensing signals in magnetic flux leakage type NDT
Author
Seo, Kang ; Han, Jae Man ; Park, Gwan Soo
Author_Institution
Pusan Nation Univ., Pusan
fYear
2007
fDate
8-11 Oct. 2007
Firstpage
1932
Lastpage
1935
Abstract
Sensitive detection of the defect signals in NDT system is critical. Because of a strong magnetic field in magnetic flux type NDT system, the object itself is magnetized and shows a hysteresis characteristics during the sensing, which might cause a distortion of the defect signals. In this research, the magnetization characteristics of a pipeline in the magnetic flux leakage type non-destructive testing are analyzed. Effects of a magnetic hysteresis of a pipeline are analyzed by Preisach modeling and a magnetic flux density due to a remanent magnetization of gas pipeline is computed and verified by real measurement.
Keywords
magnetic fields; magnetic flux; magnetic hysteresis; magnetic leakage; nondestructive testing; pipelines; remanence; gas pipeline; hysteresis; magnetic field; magnetic flux density; magnetic flux leakage; nondestructive testing system; remanent magnetization; sensing signals; Distortion; Magnetic analysis; Magnetic fields; Magnetic flux; Magnetic flux density; Magnetic flux leakage; Magnetic hysteresis; Magnetization; Nondestructive testing; Pipelines; magnetic flux leakage; magnetic sensor; non destructive testing; nonlinear finite element analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2007. ICEMS. International Conference on
Conference_Location
Seoul
Print_ISBN
978-89-86510-07-2
Electronic_ISBN
978-89-86510-07-2
Type
conf
Filename
4412128
Link To Document