• DocumentCode
    469435
  • Title

    The high resolution electromagnetic calorimeter for Panda - a Status Report -

  • Author

    Novotny, R.W.

  • Author_Institution
    Univ. Giessen, Giessen
  • Volume
    1
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    161
  • Lastpage
    165
  • Abstract
    A high resolution electromagnetic calorimeter has been proposed as one of the major detector components of the future PANDA detector at FAIR The homogeneous calorimeter is based on high quality PWO-II scintillator crystals operated at a temperature of T=-25degC and readout via large area avalanche photo diodes. The paper summarizes the status of the detector performance, radiation hardness and the present layout of the whole target calorimeter.
  • Keywords
    avalanche photodiodes; lead compounds; nuclear electronics; particle calorimetry; radiation hardening; readout electronics; solid scintillation detectors; High Resolution Electromagnetic Calorimeter; PANDA; PbWO4; avalanche photo diodes; detector components; detector performance; radiation hardness; read out system; scintillator crystals; target calorimeter; temperature -25 C; Crystals; Detectors; Electromagnetic compatibility; Electromagnetic measurements; Electromagnetic radiation; Energy resolution; Large Hadron Collider; Magnetic field measurement; Spectroscopy; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436308
  • Filename