DocumentCode
46950
Title
A statistical model for the ultrasonic backscattered echo from tissue containing microcalcifications
Author
Shankar, P.M.
Author_Institution
Dept. of Electr. & Comput. Eng., Drexel Univ., Philadelphia, PA, USA
Volume
60
Issue
5
fYear
2013
fDate
May-13
Firstpage
932
Lastpage
942
Abstract
Microcalcifications, generally seen in B-mode breast images as bright spots, often point to the presence of malignancies. Currently, statistical models to describe the signal strengths from tissue containing microcalcifications rely on the Rician or Nakagami densities. Because the Nakagami density requires the existence of randomly located scatterers with random cross sections, microcalcifications manifesting as isolated strong scatterers in the scattering volume makes it less suitable. Additionally, the absence of any regularly spaced scatterers also makes the Rician density less suitable. In this work, it is proposed that a 3-parameter McKay density with heavier tails than the Nakagami density, and hence more severe intensity fluctuations (speckle), might be a better fit to describe echo from tissue containing microcalcifications. This density is developed using a physical description of scattering and its characteristics are explored through random number simulation. Results demonstrate that the McKay densities have higher levels of speckle quantified through the speckle factor than the corresponding gamma densities (Nakagami for the envelope). Some preliminary analysis of tissue-mimicking phantoms modified to include microcalcification-like regions shows that higher speckle factors (seen with the McKay density) can be used to isolate and display microcalcifications. It is expected that this novel approach based on the McKay density will lead to newer and simpler means to detect and identify microcalcifications in ultrasonic B-scans.
Keywords
bio-optics; bioacoustics; biological tissues; biomedical ultrasonics; biomimetics; echo; phantoms; speckle; statistical analysis; B-mode breast images; Nakagami density; Rician density; gamma densities; intensity fluctuations; malignancies; microcalcification; random number simulation; scattering volume; signal strengths; speckle factor; speckle levels; statistical model; three-parameter McKay density; tissue-mimicking phantoms; ultrasonic B-scans; ultrasonic backscattered echo; Calcinosis; Computer Simulation; Image Processing, Computer-Assisted; Models, Biological; Models, Statistical; Phantoms, Imaging; Signal Processing, Computer-Assisted; Ultrasonography, Mammary;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2013.2650
Filename
6512830
Link To Document