• DocumentCode
    469729
  • Title

    First measurements for the SiliPET project: A small animal PET scanner based on stacks of silicon detectors

  • Author

    Auricchio, N. ; Domenico, G. Di ; Zavattini, G. ; Gola, A. ; Fiorini, C. ; Frigerio, M. ; Ambrosi, G. ; Ionica, M. ; Fiandrini, E. ; Zorzi, N. ; Boscardin, M.

  • Author_Institution
    Univ. of Ferrara, Ferrara
  • Volume
    4
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    2926
  • Lastpage
    2929
  • Abstract
    We have proposed a new scanner for small-animal positron emission tomography (PET) based on stacks of double sided silicon detectors. Each stack is composed of 40 planar detectors with dimension 60 times 60 times 1 mm3 and 128 orthogonal strips on both sides to read the two coordinates of interaction, the third being the detector number in the stack. Multiple interactions in a stack may be discarded. In this way we achieve a precise determination of the interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results were obtained with MEGA prototype tracker. In this work we present the results obtained with double sided silicon detectors, manufactured by ITC-Fondazione Bruno Kessler (Trento- Italy), having an active area of 3 times 3 cm2, a strip pitch of 500 mum, strip width of 300 mum and thickness of 1 mm, equipped with 64 orthogonal p and n strips on opposite sides. We are using two different kinds of analog front end electronic chains: a single channel prototype of an ASIC circuit designed by Politecnico di Milano for fast timing measurements and VATAGP2.5 ASIC by IDEAS to evaluate the spatial resolution.
  • Keywords
    biomedical equipment; elemental semiconductors; positron emission tomography; silicon; solid scintillation detectors; ASIC circuit; Si; VATAGP2.5 ASIC; double sided silicon detectors; fast timing measurements; planar detectors; positron emission tomography; size 1 mm; size 300 mum; size 60 mm; small-animal PET scanner; spatial resolution; strip pitch; strip thickness; strip width; Animals; Application specific integrated circuits; Detectors; Manufacturing; Positron emission tomography; Prototypes; Silicon; Solids; Strips; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436746
  • Filename
    4436746