• DocumentCode
    469934
  • Title

    A compact scintillator-based coded aperture imager for localizing illicit nuclear materials

  • Author

    Vaska, P. ; Vanier, P.E. ; Junnarkar, S. ; Krishnamoorthy, S. ; Pratte, J.-F. ; Stoll, S.

  • Author_Institution
    Brookhaven Nat. Lab., Upton
  • Volume
    2
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    1195
  • Lastpage
    1197
  • Abstract
    Efficient detection, localization, and identification of illicit nuclear materials is a critical need for national security. Gamma-ray signatures can be exploited for these purposes, but very high detection efficiency is needed in addition to a practical design that can be effective in the field. Modern, dense scintillators with low intrinsic background provide the highest detection efficiency (albeit at somewhat lower energy resolution than semiconductor detectors), and solid-state photodetector readout of the scintillation light can enable a compact and robust design compared to conventional photomultiplier tubes. We explore the feasibility of a coded aperture gamma-ray imager which combines gadolinium oxyorthosilicate scintillator (GSO) and avalanche photodiode (APD) readout. Each GSO crystal is 5 times 5 mm in cross-section and 25 mm long, and is coupled to a Hamamatsu S8664-55 APD with matching active area. 225 detectors are arrayed in a 15 times 15 matrix within a tungsten shield box. Readout is effected with a custom PC board which includes multiple 32-channel ASICs to handle preamplification, shaping, and energy and time discrimination. The output is fed to a compact data acquisition system originally designed for medical imaging with the RatCAP PET system. Various coded aperture designs are being evaluated for optimal imaging performance. Detector design and performance are presented.
  • Keywords
    application specific integrated circuits; avalanche photodiodes; data acquisition; gamma-ray apparatus; hazardous materials; national security; nuclear electronics; readout electronics; scintillation counters; solid scintillation detectors; 32-channel ASIC; Hamamatsu S8664-55 APD; avalanche photodiode readout; coded aperture gamma-ray imager; compact scintillator-based coded aperture imager; data acquisition system; gadolinium oxyorthosilicate scintillator; illicit nuclear material localization; size 25 mm; size 5 mm; solid-state photodetector readout; Apertures; Energy resolution; Gamma ray detection; Gamma ray detectors; National security; Photodetectors; Photomultipliers; Robustness; Solid scintillation detectors; Solid state circuits;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4437220
  • Filename
    4437220