An All-Ultrasound-Based System for Real-Time Monitoring and Sonication of Temperature Change and Ablation
Author
Maleke, Caroline ; Konofagou, Elisa E.
Author_Institution
Dept. of Biomed. Eng., Columbia Univ., New York, NY
fYear
2006
fDate
Aug. 30 2006-Sept. 3 2006
Firstpage
164
Lastpage
167
Abstract
Previously, we introduced a new harmonic motion imaging (HMI) technique for simultaneous monitoring and generation of ultrasound therapy treatment using a single element focused-ultrasound and one pulse-echo transducer. The new HMI technique uses an amplitude-modulated beam (instead of using two beams) that has a stable focal zone for the applied harmonic radiation force. The harmonic radiation force was generated by a 4.68 MHz focused transducer and a 7.5 MHz pulse-echo transducer was used to acquire RF echoes. The RF echoes were recorded and used to estimate tissue displacements during sonication. The new HMI technique has been shown to provide tissue displacement information during ultrasound therapy. In this paper, a study on the temperature dependence of the new HMI method is presented. The sonication time used applied was approximately equal to 80 seconds at maximum acoustic intensity of 658 W/cm2 at the focus. The experiments were performed on bovine tissues in vitro. The results show that the temperature elevation at the focal zone during sonication rises rapidly until it reaches a temperature higher than 50degC, which produces tissue damage. The new HMI technique provides temperature-related tissue displacement changes using the same transducer, which makes it simple for monitoring temperature rise and lesions formation during high intensity focused ultrasound (HIFU) treatment
Keywords
biological tissues; biomedical transducers; biomedical ultrasonics; biothermics; patient treatment; ultrasonic transducers; 4.68 MHz; 7.5 MHz; 80 sec; HIFU treatment; RF echoes; acoustic intensity; amplitude-modulated beam; applied harmonic radiation force; harmonic motion imaging technique; high intensity focused ultrasound treatment; lesions formation; one pulse-echo transducer; single element focused-ultrasound transducer; sonication time; temperature elevation; temperature monitoring; temperature-related tissue displacement; Acoustic beams; Focusing; Medical treatment; Monitoring; Pulse generation; Radio frequency; Real time systems; Temperature; Ultrasonic imaging; Ultrasonic transducers;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location
New York, NY
ISSN
1557-170X
Print_ISBN
1-4244-0032-5
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/IEMBS.2006.260845
Filename
4461710
Link To Document