• DocumentCode
    471369
  • Title

    An All-Ultrasound-Based System for Real-Time Monitoring and Sonication of Temperature Change and Ablation

  • Author

    Maleke, Caroline ; Konofagou, Elisa E.

  • Author_Institution
    Dept. of Biomed. Eng., Columbia Univ., New York, NY
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 3 2006
  • Firstpage
    164
  • Lastpage
    167
  • Abstract
    Previously, we introduced a new harmonic motion imaging (HMI) technique for simultaneous monitoring and generation of ultrasound therapy treatment using a single element focused-ultrasound and one pulse-echo transducer. The new HMI technique uses an amplitude-modulated beam (instead of using two beams) that has a stable focal zone for the applied harmonic radiation force. The harmonic radiation force was generated by a 4.68 MHz focused transducer and a 7.5 MHz pulse-echo transducer was used to acquire RF echoes. The RF echoes were recorded and used to estimate tissue displacements during sonication. The new HMI technique has been shown to provide tissue displacement information during ultrasound therapy. In this paper, a study on the temperature dependence of the new HMI method is presented. The sonication time used applied was approximately equal to 80 seconds at maximum acoustic intensity of 658 W/cm2 at the focus. The experiments were performed on bovine tissues in vitro. The results show that the temperature elevation at the focal zone during sonication rises rapidly until it reaches a temperature higher than 50degC, which produces tissue damage. The new HMI technique provides temperature-related tissue displacement changes using the same transducer, which makes it simple for monitoring temperature rise and lesions formation during high intensity focused ultrasound (HIFU) treatment
  • Keywords
    biological tissues; biomedical transducers; biomedical ultrasonics; biothermics; patient treatment; ultrasonic transducers; 4.68 MHz; 7.5 MHz; 80 sec; HIFU treatment; RF echoes; acoustic intensity; amplitude-modulated beam; applied harmonic radiation force; harmonic motion imaging technique; high intensity focused ultrasound treatment; lesions formation; one pulse-echo transducer; single element focused-ultrasound transducer; sonication time; temperature elevation; temperature monitoring; temperature-related tissue displacement; Acoustic beams; Focusing; Medical treatment; Monitoring; Pulse generation; Radio frequency; Real time systems; Temperature; Ultrasonic imaging; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.260845
  • Filename
    4461710