DocumentCode
474292
Title
Manipulation of Biological Samples using Electric Field
Author
Iliescu, Ciprian ; Xu, Guo Lin ; Ong, Poh Lam ; Yu, Liming ; Tay, Francis E H ; Iliescu, Florina Silvia ; Tresset, G.
Author_Institution
Inst. of Bioeng. & Nanotechnol., Singapore
Volume
1
fYear
2007
fDate
Oct. 15 2007-Sept. 17 2007
Firstpage
67
Lastpage
76
Abstract
The paper presents original contributions at manipulation of biological samples using electric field (dielectrophoresis). Design considerations, fabrication processes and experimental results of three original three dimensional (3D) dielectrophoretic (DEP) structures: DEP chip with 3D silicon electrodes, DEP chip with 3D electric field gradient and 3D filtering chip are analyzed. The paper presents also the experimental results of trapping yeast cells.
Keywords
biological techniques; electric field effects; electric field gradient; electrodes; electrophoresis; elemental semiconductors; microfluidics; silicon; 3D electric field gradient; 3D filtering chip; 3D silicon electrodes; Si; biological samples; dielectrophoresis; yeast cells; Biomedical engineering; Dielectric thin films; Dielectrophoresis; Electrodes; Fabrication; Fungi; Glass; Microfluidics; Shape; Silicon; 3D dielectrophoresis; cell manipulation; microfluidics;
fLanguage
English
Publisher
ieee
Conference_Titel
Semiconductor Conference, 2007. CAS 2007. International
Conference_Location
Sinaia
ISSN
1545-827X
Print_ISBN
978-1-4244-0847-4
Type
conf
DOI
10.1109/SMICND.2007.4519649
Filename
4519649