• DocumentCode
    475012
  • Title

    Nonlinear EPSAC predictive control of blood glucose level in diabetic patients for prandial disturbance rejection

  • Author

    Hodrea, R. ; Ionescu, C.M. ; Keyser, R. De ; Nascu, I.

  • Author_Institution
    Tech. Univ. of Cluj-Napoca, Cluj-Napoca
  • Volume
    2
  • fYear
    2008
  • fDate
    22-25 May 2008
  • Firstpage
    180
  • Lastpage
    185
  • Abstract
    The nonlinear EPSAC (NEPSAC) predictive control algorithm has been implemented to regulate blood glucose level in type I diabetic patients, by controlling the insulin infusion rate with a micropump. The advantage of the NEPSAC strategy is that the nonlinear process is never linearized, thus it uses directly the nonlinear patient model. The role of the disturbance filter in model-based predictive control is underlined and its possibility to improve control performance is exploited. A default disturbance filter, consisting of an integrator to ensure zero steady-state error, is compared to an intelligent filter design with output constraints. Controller performance was assessed in terms of its ability to reject typical prandial (meal) disturbances of 20 g, 40 g and 30 g glucose.
  • Keywords
    blood; medical control systems; micropumps; nonlinear control systems; predictive control; blood glucose level; diabetic patients; disturbance filter; insulin infusion rate; micropumps; model-based predictive control; nonlinear EPSAC predictive control; nonlinear process; prandial disturbance rejection; steady-state error; Blood; Diabetes; Filters; Insulin; Micropumps; Prediction algorithms; Predictive control; Predictive models; Steady-state; Sugar;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Automation, Quality and Testing, Robotics, 2008. AQTR 2008. IEEE International Conference on
  • Conference_Location
    Cluj-Napoca
  • Print_ISBN
    978-1-4244-2576-1
  • Electronic_ISBN
    978-1-4244-2577-8
  • Type

    conf

  • DOI
    10.1109/AQTR.2008.4588817
  • Filename
    4588817