DocumentCode
476393
Title
Calibration of a Multicamera Network
Author
Baker, Patrick T. ; Aloimonos, Yiannis
Author_Institution
University of Maryland, College Park
Volume
7
fYear
2003
fDate
16-22 June 2003
Firstpage
72
Lastpage
72
Abstract
With the advent of laboratories containing dozens of cameras, and the possibility of laboratories containing hundreds of cameras, the question of how to calibrate all the cameras has become pressing. While it is certainly possible to calibrate these networks in a labor intensive manner, a simple, stable, and accurate calibration method is still needed. This paper presents such a method, based on textures printable on a laser printer and mounted on a board. We will show what the problems with the current methods are, and show how these problems can be overcome with a novel use of a trilinear constraint related to the vanishing point constraint, which we call the primsatic line constraint. High accuracy with little user effort is achieved with this method.
Keywords
Automation; Calibration; Cameras; Clothing; Data mining; Educational institutions; Laboratories; Light emitting diodes; Pixel; Stability;