• DocumentCode
    48085
  • Title

    Research on a Novel Modulation Strategy for Auxiliary Resonant Commutated Pole Inverter With the Smallest Loss in Auxiliary Commutation Circuits

  • Author

    Enhui Chu ; Mengyang Wu ; Liang Huang ; Xutong Hou ; Huaguang Zhang

  • Author_Institution
    Coll. of Inf. Sci. & Eng., Northeastern Univ., Shenyang, China
  • Volume
    29
  • Issue
    3
  • fYear
    2014
  • fDate
    Mar-14
  • Firstpage
    1103
  • Lastpage
    1117
  • Abstract
    Aiming at overcoming the problem that the auxiliary commutation circuit (ACC) of auxiliary resonant commutated pole (ARCP) inverters has a high loss in commutation processes, this paper presents a novel modulation strategy based on an improved ARCP inverter. In comparison with the original modulation strategy, this modulation strategy can not only realize soft-switching for all switches, but also avoid the superposition of resonance current and load current at commutation moments in ACCs and make the maximum current through ACCs approximately equal to load current in commutation processes. So the circulating current loss in ACCs and the current peak stress of auxiliary switches can be effectively reduced. According to the equivalent circuit in different operation modes under this modulation strategy, this paper analyses the operation principle, soft-switching implementation condition, and optimal parameter design procedure of the improved ARCP inverter. Finally, the novel modulation strategy is applied to a 10 kW 16 kHz improved ARCP inverter prototype with insulated gate bipolar transistor-based switches. Experimental results are given to demonstrate the validity and features of the inverter under the novel modulation strategy.
  • Keywords
    commutation; equivalent circuits; insulated gate bipolar transistors; power semiconductor switches; resonant invertors; switching convertors; zero voltage switching; ACC loss; ZVS; auxiliary commutation circuit loss; auxiliary resonant commutated pole inverters; auxiliary switches; circulating current loss; current peak stress reduction; equivalent circuit; frequency 16 kHz; improved ARCP inverter; insulated gate bipolar transistor-based switch; modulation strategy; operation modes; optimal parameter design; power 10 kW; soft-switching implementation; zero voltage switching; Capacitors; Inductors; Modulation; RLC circuits; Resonant inverters; Topology; Auxiliary commutation circuit (ACC); modulation strategy; resonant commutated pole inverter; soft-switching; zero voltage switching (ZVS);
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2013.2261092
  • Filename
    6513315