• DocumentCode
    482263
  • Title

    Applied engineering design of Three Gorges’ 840MVA hydro-generator with close loop self circulating evaporative cooling system

  • Author

    Yuan, Jiayi ; Gu, Guobiao ; Ruan, Lin ; Tian, Xindong ; Duo, Lin ; Zhang, Tianpeng

  • Author_Institution
    Inst. of Electr. Eng., Chinese Acad. of Sci., Beijing
  • fYear
    2008
  • fDate
    17-20 Oct. 2008
  • Firstpage
    142
  • Lastpage
    145
  • Abstract
    In this paper, we introduce an applied engineering design of Three Gorgespsila 840 MVA hydro-generator with close loop self circulating evaporative cooling (CLSCEC) System and its designing principles. We also make a comparison between the internal water cooling (IWC) hydro-generator used in Three Gorges power plant and the new CLSCEC hydro-generator in fields of their operating characteristics, working performances, technical features, working safety and reliability. In addition, based on the design permanents, engineering structures, modeling tests results and systematic emulating calculation of CLSCEC schemes are analyzed.
  • Keywords
    cooling; hydroelectric power; close loop self circulating evaporative cooling system; hydro-generator; internal water cooling; Cooling; Design engineering; Power engineering and energy; Power generation; Power system modeling; Power system reliability; Reliability engineering; Safety; System testing; Water;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-3826-6
  • Electronic_ISBN
    978-7-5062-9221-4
  • Type

    conf

  • Filename
    4770667