DocumentCode
482402
Title
An in-site system based-on ARM of faults diagnostic with the amplitude recovery method
Author
Liu, Yukun ; Guo, Liwei ; Sun, Xiaoyun ; An, Guoqing
Author_Institution
Coll. of Inf. Sci. & Eng., Hebei Univ. of Sci. & Technol., Shijiazhuang
fYear
2008
fDate
17-20 Oct. 2008
Firstpage
746
Lastpage
750
Abstract
A new harmonic analysis method - the amplitude recovery method - is addressed and is used in the in-site faults diagnostic in induction motors. To practice this method, an in-site and portable system of faults diagnostic in induction motors on ARM (advanced RISC machines) is also addressed. S3C2410 ARM is chosen as the core of this system. Its faster and multi-channel ADC subsystem and small size can meet the needs of the real-time and in-situation test on induction motors. With the help of the PC and the current spectrum analysis, this ARM system can be used to diagnose the faults in induction motors. Even better, having the aid of the small-sized PC, Vortex86-6082, a reliable and portable system can be realized to meet the purpose of testing and diagnosing the faults of induction motors in-situation.
Keywords
amplitude estimation; fault diagnosis; harmonic analysis; induction motors; machine testing; reduced instruction set computing; ARM; S3C2410 ARM; Vortex86-6082; advanced RISC machines; amplitude recovery method; current spectrum analysis; fault diagnosis; fault diagnostics; harmonic analysis method; in-site system; induction motors; motor testing; small-sized PC; Digital signal processing; Educational institutions; Harmonic analysis; Induction motors; Laboratories; Machine control; Manufacturing; Rotors; Stator windings; System testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-3826-6
Electronic_ISBN
978-7-5062-9221-4
Type
conf
Filename
4770806