• DocumentCode
    485668
  • Title

    Acceleration Measurements in a High G Environment

  • Author

    Pilcher, James O.

  • Author_Institution
    Ballistic Research Laboratory, USAARRADCOM, Aberdeen Proving Ground, MD 21005
  • fYear
    1982
  • fDate
    14-16 June 1982
  • Firstpage
    950
  • Lastpage
    954
  • Abstract
    This paper discusses the problem of measuring specific acceleration parameters in the high G dynamic environments of ballistic system components such as gun tubes and projectiles. The discussion includes: (1) Characteristics of the acceleration environment. (2) Mechanical filtering techniques required to separate measurands from stress wave interference. (3) Sensor array technique required to discriminate vector components of the measurand. (4) Electronic and numerical filtering techniques and their dangers. (5) Calibration and sensor response requirements. Data example will be given illustrating the problems and solutions.
  • Keywords
    Acceleration; Accelerometers; Filtering; Interference; Mechanical sensors; Mechanical variables measurement; Projectiles; Sensor arrays; Sensor phenomena and characterization; Stress measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    American Control Conference, 1982
  • Conference_Location
    Arlington, VA, USA
  • Type

    conf

  • Filename
    4787997