    Measurement of Dense-Phase Bed Height in CFB Boiler Based on Flame Image Processing Technique

  • Author

    Luo, Zi-Xue ; Wang, Dun-Dun ; Duan Lian ; Zhou, Huai-Chun

  • Author_Institution
    State Key Lab. of Coal Combustion, Huazhong Univ. of Sci. & Technol., Wuhan, China
  • Volume
    1
  • fYear
    2009
  • fDate
    11-12 April 2009
  • Firstpage
    237
  • Lastpage
    240
  • Abstract
    This paper proposes a method to measure the dense-phase bed height by edge-detection of Charge Coupled Device based on flame image processing technique in Circulated Fluidized Bed (CFB) boiler. The detection system was installed in a 480t/h CFB boiler, image processing model has been built,and in-situ experiment was carried out. Real-time bed height is reliable and meets the bed pressure drop exactly in furnace. The monitoring equipment, the flame image processing theory of recognition algorithm, and the choice of the threshold value of gray, are introduced in the paper. This image processing technique can provide CFB boiler with the safe, economic and clean operation in practical industry application.
  • Keywords
    boilers; charge-coupled devices; edge detection; flames; fluidised beds; image processing; CFB boiler; charge coupled device; circulated fluidized bed boiler; dense-phase bed height; edge-detection; flame image processing technique; Boilers; Charge measurement; Charge-coupled image sensors; Current measurement; Fires; Fluidization; Furnaces; Image edge detection; Image processing; Monitoring; CFB boiler; dense-phase bed height; detection component; flame image processing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Measuring Technology and Mechatronics Automation, 2009. ICMTMA '09. International Conference on
  • Conference_Location
    Zhangjiajie, Hunan
  • Print_ISBN
    978-0-7695-3583-8
  • Type

    conf

  • DOI
    10.1109/ICMTMA.2009.397
  • Filename
    5202956