DocumentCode :
502602
Title :
Cable discharges into communication interfaces
Author :
Stadler, W. ; Brodbeck, T. ; Gartner, R. ; Gossner, Harald
Author_Institution :
Infineon Technol. AG, Munich, Germany
fYear :
2006
fDate :
10-15 Sept. 2006
Firstpage :
144
Lastpage :
151
Abstract :
Current amplitudes of a cable discharge event (CDE) are a risk for electronic interfaces if a cable can discharge directly into a signal pin. CDE have been recorded for several cables in different configurations. CDE can be modeled by square pulses, thus, Transmission Line Pulsing is a good approach for characterizing interface pins and protection elements.
Keywords :
electrostatic discharge; telecommunication cables; transmission lines; CDE; ESD; cable discharge event; communication interfaces; current amplitudes; electronic interfaces; interface pins; protection elements; signal pin; square pulses; transmission line pulsing; Cable TV; Communication cables; Communication standards; Electrostatic discharge; Firewire; Mobile communication; Power cables; Protection; Stress; Universal Serial Bus;