• DocumentCode
    504654
  • Title

    Modeling of gas governor system with venturi

  • Author

    Okada, Kunio ; Takeuti, Tomoaki ; Youn, Chongo ; Kagawa, Toshiharu

  • Author_Institution
    Tokyo Inst. of Technol., Yokohama, Japan
  • fYear
    2009
  • fDate
    18-21 Aug. 2009
  • Firstpage
    3347
  • Lastpage
    3352
  • Abstract
    The AFV is often used as gas governor to control pressure in gas pipeline. The AFV has a pilot line to control the downstream pressure. The pilot line consists of pilot valve and restrictor. An orifice or venturi is used for the restrictor. However, the modeling of pilot line with venturi is not studied yet. In this paper, we investigate the characteristics of the pilot line with venturi, and propose the modeling of pilot line. The characteristics of venturi and pilot valve are examined by using the pneumatic system. The effectiveness of the proposed modeling was confirmed by experiment.
  • Keywords
    pipelines; pneumatic systems; pressure control; axial flow valve; downstream pressure control; gas governor system modeling; gas pipeline; orifice; pilot valve; pneumatic system; restrictor; venturi; Cities and towns; Electrical equipment industry; Industrial control; Orifices; Pipelines; Pneumatic systems; Pressure control; Rubber; Springs; Valves; Industrial Applications-Components and Devices; Industrial Applications-Transportation Systems; Measurement-Flow Measurement and Control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    ICCAS-SICE, 2009
  • Conference_Location
    Fukuoka
  • Print_ISBN
    978-4-907764-34-0
  • Electronic_ISBN
    978-4-907764-33-3
  • Type

    conf

  • Filename
    5334329