• DocumentCode
    50748
  • Title

    Fault Detection in Nuclear Power Plants Components by a Combination of Statistical Methods

  • Author

    Di Maio, Francesco ; Baraldi, Piero ; Zio, Enrico ; Seraoui, Redouane

  • Author_Institution
    Energy Dept., Politec. di Milano, Milan, Italy
  • Volume
    62
  • Issue
    4
  • fYear
    2013
  • fDate
    Dec. 2013
  • Firstpage
    833
  • Lastpage
    845
  • Abstract
    In this paper, we investigate the feasibility of a strategy of fault detection capable of controlling misclassification probabilities, i.e., balancing false and missed alarms. The novelty of the proposed strategy consists of i) a signal grouping technique and signal reconstruction modeling technique (one model for each subgroup), and ii) a statistical method for defining the fault alarm level. We consider a real case study concerning 46 signals of the Reactor Coolant Pump (RCP) of a typical Pressurized Water Reactor (PWR). In the application, the reconstructions are provided by a set of Auto-Associative Kernel Regression (AAKR) models, whose input signals have been selected by a hybrid approach based on Correlation Analysis (CA) and Genetic Algorithm (GA) for the identification of the groups. Sequential Probability Ratio Test (SPRT) is used to define the alarm level for a given expected classification performance. A practical guideline is provided for optimally setting the SPRT parameters´ values.
  • Keywords
    correlation methods; fault diagnosis; genetic algorithms; nuclear power stations; power system measurement; probability; statistical analysis; auto-associative Kernel regression models; balancing false; correlation analysis; fault detection; genetic algorithm; misclassification probabilities; missed alarms; nuclear power plants; pressurized water reactor; reactor coolant pump; sequential probability ratio test; statistical methods; Fault detection; Gaussian distribution; Genetic algorithms; Inductors; Signal reconstruction; Statistical analysis; Auto-associative kernel regression; condition monitoring; nuclear reactor coolant pump; sequential probability ratio test; signal grouping; signal reconstruction;
  • fLanguage
    English
  • Journal_Title
    Reliability, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9529
  • Type

    jour

  • DOI
    10.1109/TR.2013.2285033
  • Filename
    6632931