• DocumentCode
    51286
  • Title

    The Effect of Copper Coating on the Losses in the Solid Pole-Plates of Inverter-Fed Wound Rotor Synchronous Machines

  • Author

    Shisha, S. ; Sadarangani, C. ; Nee, H.-P.

  • Author_Institution
    Lab. of Electr. Machines & Power Electron., KTH R. Inst. of Technol., Stockholm, Sweden
  • Volume
    28
  • Issue
    2
  • fYear
    2013
  • fDate
    Jun-13
  • Firstpage
    298
  • Lastpage
    307
  • Abstract
    The use of solid rotor and pole-plate synchronous machines has several advantages, among which is the fact that it provides a more robust rotor compared to laminated equivalents. This paper investigates the time and space harmonic losses in solid rotor synchronous machines. The work considers the use of copper coating on the pole-plates, studying the effect that this design modification has on the losses. A recommendation is given based on this study, which is considered to reduce the time harmonic losses without detrimental effects as far as the space harmonic losses are considered.
  • Keywords
    coatings; copper; losses; rotors; synchronous machines; copper coating; inverter fed wound rotor synchronous machines; solid pole plates; solid rotor synchronous machines; space harmonic loss; time harmonic loss; Direct torque control; losses; synchronous machines; variable speed drives;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.2013.2251419
  • Filename
    6514614