DocumentCode
51286
Title
The Effect of Copper Coating on the Losses in the Solid Pole-Plates of Inverter-Fed Wound Rotor Synchronous Machines
Author
Shisha, S. ; Sadarangani, C. ; Nee, H.-P.
Author_Institution
Lab. of Electr. Machines & Power Electron., KTH R. Inst. of Technol., Stockholm, Sweden
Volume
28
Issue
2
fYear
2013
fDate
Jun-13
Firstpage
298
Lastpage
307
Abstract
The use of solid rotor and pole-plate synchronous machines has several advantages, among which is the fact that it provides a more robust rotor compared to laminated equivalents. This paper investigates the time and space harmonic losses in solid rotor synchronous machines. The work considers the use of copper coating on the pole-plates, studying the effect that this design modification has on the losses. A recommendation is given based on this study, which is considered to reduce the time harmonic losses without detrimental effects as far as the space harmonic losses are considered.
Keywords
coatings; copper; losses; rotors; synchronous machines; copper coating; inverter fed wound rotor synchronous machines; solid pole plates; solid rotor synchronous machines; space harmonic loss; time harmonic loss; Direct torque control; losses; synchronous machines; variable speed drives;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/TEC.2013.2251419
Filename
6514614
Link To Document