DocumentCode :
519176
Title :
Effect of hydrogen Purging period on system performance of PEMFC
Author :
Pokphet, T. ; Khan-ngern, W. ; Charoensuk, J.
Author_Institution :
Fac. of Eng., King Mongkut´´s Inst. of Technol. Ladkrabang, Bangkok, Thailand
fYear :
2010
fDate :
19-21 May 2010
Firstpage :
88
Lastpage :
92
Abstract :
This paper concerns with the study on the effect of hydrogen Purging period on the performance of PEMFC system. It is aimed to improve PEMFC performance to be a reliable power source for power supply unit. The membrane electrode assembly of a PEMFC (Proton Exchange Membrane Fuel Cell) has to be wet for the fuel cells to work efficiently. Despite many factors causing cell degradation and jeopardize the stack performance and attenuate the electrochemical reaction, this paper only focuses on an arrangement of hydrogen purging period to remove water droplets and residue of inert gas from the anode side of the fuel cell. Experiments show the stack performance as well as its efficiency at various purging periods at 100 W and 400 W loads.
Keywords :
fuel cell power plants; power generation reliability; proton exchange membrane fuel cells; PEMFC system; cell degradation; electrochemical reaction; hydrogen purging period; membrane electrode assembly; power 100 W; power 400 W; power supply unit; proton exchange membrane fuel cell; stack performance; system performance; Assembly; Biomembranes; Degradation; Electrodes; Fuel cells; Hydrogen; Power supplies; Power system reliability; Protons; System performance; Dead-end mode; Flow-through mode; PEMFC; Purging cycle; Purging period; Purging pulse; Recirculation mode;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Engineering/Electronics Computer Telecommunications and Information Technology (ECTI-CON), 2010 International Conference on
Conference_Location :
Chaing Mai
Print_ISBN :
978-1-4244-5606-2
Electronic_ISBN :
978-1-4244-5607-9
Type :
conf
Filename :
5491525
Link To Document :