DocumentCode
530716
Title
Influences of different excitation parameters upon PEC testing for deep-layered defect detection with rectangular sensor
Author
Hu, Xiangchao ; Luo, Feilu
Author_Institution
Coll. of Mechatron. & Autom., Nat. Univ. of Defense Technol., Changsha, China
Volume
3
fYear
2010
fDate
24-26 Aug. 2010
Firstpage
579
Lastpage
582
Abstract
In pulsed eddy current testing, repetitive excitation signals with different parameters: duty-cycle, frequency and amplitude have different response representations. This work studies the influences of different excitation parameters on pulsed eddy current testing for deep-layered defects detection of stratified samples with rectangular sensor. The sensor had been proved to be superior in quantification and classification of defects in multi-layered structures compared with traditional circular ones. Experimental results show necessities to optimize the parameters of pulsed excitation signal, and advantages of obtaining better performances to enhance the POD of PEC testing.
Keywords
aerospace materials; crack detection; eddy current testing; inspection; multilayers; probability; PEC testing; deep layered defect detection; defect classification; defect quantification; duty cycle; excitation parameters; multilayered structures; pulsed eddy current testing; rectangular sensor; repetitive pulsed excitation signals; Software; Testing; Influences of different excitation parameters; defect detection; multi-layer structur; pulsed eddy current testing; rectangular sensor;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer, Mechatronics, Control and Electronic Engineering (CMCE), 2010 International Conference on
Conference_Location
Changchun
Print_ISBN
978-1-4244-7957-3
Type
conf
DOI
10.1109/CMCE.2010.5610253
Filename
5610253
Link To Document