• DocumentCode
    530716
  • Title

    Influences of different excitation parameters upon PEC testing for deep-layered defect detection with rectangular sensor

  • Author

    Hu, Xiangchao ; Luo, Feilu

  • Author_Institution
    Coll. of Mechatron. & Autom., Nat. Univ. of Defense Technol., Changsha, China
  • Volume
    3
  • fYear
    2010
  • fDate
    24-26 Aug. 2010
  • Firstpage
    579
  • Lastpage
    582
  • Abstract
    In pulsed eddy current testing, repetitive excitation signals with different parameters: duty-cycle, frequency and amplitude have different response representations. This work studies the influences of different excitation parameters on pulsed eddy current testing for deep-layered defects detection of stratified samples with rectangular sensor. The sensor had been proved to be superior in quantification and classification of defects in multi-layered structures compared with traditional circular ones. Experimental results show necessities to optimize the parameters of pulsed excitation signal, and advantages of obtaining better performances to enhance the POD of PEC testing.
  • Keywords
    aerospace materials; crack detection; eddy current testing; inspection; multilayers; probability; PEC testing; deep layered defect detection; defect classification; defect quantification; duty cycle; excitation parameters; multilayered structures; pulsed eddy current testing; rectangular sensor; repetitive pulsed excitation signals; Software; Testing; Influences of different excitation parameters; defect detection; multi-layer structur; pulsed eddy current testing; rectangular sensor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer, Mechatronics, Control and Electronic Engineering (CMCE), 2010 International Conference on
  • Conference_Location
    Changchun
  • Print_ISBN
    978-1-4244-7957-3
  • Type

    conf

  • DOI
    10.1109/CMCE.2010.5610253
  • Filename
    5610253