DocumentCode
533497
Title
“Resonance verification of Tehran-Karaj electrical railway”
Author
Mahdavizadeh, Fazel
Author_Institution
Iust, Iran
fYear
2010
fDate
14-15 Sept. 2010
Firstpage
1
Lastpage
1
Abstract
In this paper analyses results of harmonic and resonance behavior of Tehran-Karaj electric railway are presented. This special electric traction system supplied by 225 kV Autotransformers (ATs) in the west side and a simple mode (without any return feeder) in the east side is considered here where the east side will be equipped with ATs in future development. Also, some parameters which can change quantity and extremity of resonance are explored. For harmonic analysis, Total Harmonic Distortion (THD) factor and Total Demand Distortion (TDD) factor are assessed. To detect the resonance points of the traction power system, harmonic frequency scans are applied. Harmonic analysis of the model is simulated by PSCAD/EMTDC software.
Keywords
Overhead Catenary System; Pscad/emtdc; Resonace Analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Quality Conference (PQC), 2010 First
Conference_Location
Tehran, Iran
Print_ISBN
978-1-4244-8483-6
Electronic_ISBN
978-964-463-063-7
Type
conf
Filename
5624707
Link To Document